A+ Fire and Security Ltd., fire alarms, residential security, systems, london, ontario, security services, sprinklers, parts, 24hr service, installations, detectors
VIGILANT
Part Number
Part Description
PDF File
Addressable Input / Output Modules
235196P
Transient Protector - for bell and horn circuits. Provides transient protection to - CC1,
CC2, MCC2, UM, and MAB Modules.
GSA-CC1
Single Inuput (Riser) Module. Features a built in RING TONE Generator, use for
switching a single signal or audio circuit.
GSA-CC1S
Single Inuput (Riser) Module. Features a built in RING TONE Generator, use for
switching a single signal or audio circuit. Also includes Strobe Synchronization.
GSA-CR
Control Relay Module. Select for either N.O. or N. C. Operation. Rated at 2 Amps/
24Vdc.
GSA-CRR
Polarity Reversal Relay Module. Reverses polarity of 24Vdc to sound a group of audible
bases.
GSA-CT1
Single Input Module. Single circuit input module for use with Normally Open Contact
Devices. Four selectable personality codes for alarm latching, alarm delaying latching,
non latching monitor, or latching supervisory.
GSA-CT2
Dual Input Module. Two Circuit Input Module for use with Normally Open Contact
Devices Four selectable personality codes on each cicuit for alarm latching, alarm
delaying latching, non latching monitor,or latching supervisory.
GSA-IM
Isolator Module. Use to isolate wiring faults on Class A - (style 7) loops.
GSA-MAB
Universal Class A/B Module - UIO Mount.
GSA-MCC1
Single Inuput (Riser) Module - UIO Mount.
GSA-MCC1S
Single Inuput (Riser) Module, UIO Mount. Also includes Strobe Synchronization.
GSA-MCR
Control Relay Module- UIO Mount.
GSA-MCRR
Polarity Reversal Relay Module - UIO Mount.
GSA-MCT2
Dual Input Module - UIO Mount.
GSA-MP1
GSA Module Mounting Plate, 1 footprint. Space for up to four 2 gang GSA Modules
or, eight 1 gang GSA Modules.
GSA-MP2
GSA Module Mounting Plate, 1/2 footprint. Space for up to two 2 gang GSA Modules
or four 1 gang GSA Modules.
GSA-MP2L
GSA Module Mounting Plate, 1/2 extended footprint. Space for up to three 2 gang GSA
Modules, or six 1 gang GSA Modules.
GSA-UIO2R
Universal Input/output Module Motherboard - 2 Position w/Riser selection. Use for M
Series Modules.
GSA-UIO6R
Universal Input/output Module Motherboard - 6 Position w/Riser selection. Use for M
Series Modules.
GSA-UIO6
Universal Input/output Module Motherboard - 6 Position, use for M Series Modules.
GSA-UM
Universal Class A/B Module. Select from 15 personality codes including Class A or
Class B Initiating circuits, Class A or B signalling circuits.
GSA-WTM
Combination Water flow / Tamper Module. Two circuit input module for use with
Normally Open Contact Devices.The first circuit is factory programmed latch as an
alarm after a contact closure of 16 seconds in duration. The second input will latch as a
Supervisory input upon closure of a Normally Open Contact.
MFC-A
Multifunction Fire Cabinet - 8" x 14" x 3.5" Red. Supports one MP1, two MP2 GSA
Mounting Plates, or one URSM, or one UIO2R, one UIO6, or one UIO6R GSA
plug in module motherboards, or one REL GSA Releasing Module.
GSA-IO
Input / Output Module.
GSA-MB4
Module Mounting Bracket kit for two single gang Modules in a 4" square box.
GSA-MDM
Digital Message Module - UIO Mount.
GSA-MIO
Input / Output Module - UIO Mount.
GSA-MRM1
Riser Monitor Module - UIO Mount, monitors one Riser.
GSA-CC2
Dual Input Riser Module - Use for switching (selecting) either of two signal or audio
input circuits to one signal output circuit.
GSA-MCC2
Dual Input Riser Module - UIO Mount.
GSA-REL
Signature Releasing Module.
GSA-RM1
Riser Monitor Module - Monitors 1 Riser.
MIRCOM
MIX-M500M
Intelligent Addressable Monitor Module - provides an address for a group of normally open initiating
devices, such as heat detectors, beam smoke detectors, 4 wire smoke detectors, waterflow switches,
manual pull stations, etc.
MIX-M500DM
Intelligent Addressable Dual Monitor Module - provides two independent 2 wire initiating device circuits
at two seperate, consecutive addresses, Monitors two seperate Class B Circuits, Ideal for water flow &
tamper switch monitoring.
MIX-M502M
Intelligent Addressable Interface Module - provides the same features as the MIX-M500M, but also
allows for the use of multiple, conventional 2-wire smoke detectors in the circuit, Requires a resettable
signal power source.
MIX-M501M
Intelligent Addressable Mini Monitor Module - provides an address for a group of Normally Open
Initiating devices such as Heat detectors, projected beam smoke detectors, 4 wire smoke detectors,
waterflow switches, manual pull stations, etc.
MIX-M500S
Intelligent Addressable Supervised Control Module - provides supervised monitoring of wiring to signal
devices that require an external power supply to operate, such as horns, strobes, bells or speaker
isolatorsConventional signals will require a 24 Vdc power source and speakers will require an audio
input - Doesnot supervise power source, a relay is required.
MIX-M500R
Intelligent Addressable Relay Module - connects to the same loop as the initiating devices and provides
two isolated sets of Form-C contacts. Module allows the FX-2000 to switch these contacts on comand.
M500X
Fault Isolator Module - Used to protect the system against wire-to-wire short circuits on the analog loop,
In the event of a short circuit between any two fault isolator modules, both modules immediately switch
to an open circuit condition and isolate any group of sensors between them (Must be wired in Class A).
CR-6 Six Relay Control Module - Consists of six Form-C relays.
SC-6 Six Supervised Control Module - provides supervised monitoring of wiring to load devices that require an
external power supply or amplifier to operate.
CZ-6 Six Zone Interface Module - provides an interface between the intelligent alarm system and a two-wire
conventional detection zone.
© A+ Fire and Security Ltd.