Vigilant VS
Part Number
Part Description
PDF File
Annunciators
RLCD
Remote Annunciator, 80 character LCD, Common System Indicators, beige housing,
mounts to 4" box with supplied ring.
RLCD-R
LCD Annunciator, 4x20 LCD, with common LEDs, Red.
RLCD-C
Remote Annunciator, 80 character LCD, Common System Indicators with Controls,
beige housing, mounts to 4" box with supplied ring.
RLCD-CR
LCD Annunciator, 4x20 LCD, with common LEDs and switches, Red.
RLED-C
Remote Annunciator, 16 zone, with 2 LEDs per zone, customizable insert labels,
Common System Indicators and Controls, beige housing, mounts to 4" box with
supplied ring.
RLED-CR
LED Annunciator, Yellow/Red LEDs for 16 zones, Common System Indicators with
Controls, Red.
RLED-24
Remote Annunciator Expander, with 2 LEDs per zone, beige housing, mounts to 4" box
with supplied ring. Requires RLCD, RLCD-C, or RLED-C master.
RLED-24R
LED Annunciator, Yellow/Red LEDs for 24 zone, Red.
RA-ENC1
Single and remote annunciator enclosure, 4" box mount, key locked door, plexiglass
window, beige.
RA-ENC2
Dual and remote annunciator enclosure, 4" box mount, key locked door, plexiglass
window, beige.
RA-ENC3
3 Unit remote annunciator enclosure, 4" box mount, key locked door, plexiglass
window, beige.
RKEY
Remote Key Switch. Single gang mount. Provides keyed control to enable / disable
common control switches on remote annunciators.
LSRA-SB
Surface mount box, for R Series units.
GCI
Graphic Annunciator Drivers, ( comes with a snap track for mounting in custom
graphic enclosures ). Provides output for common indicators and 32 alarm /
supervised zones as well as inputs for common switches.
FireShield
Part Number
Part Description
PDF File
Annunciators / Indicators / Trim Plates / Driver
FSRA-10
10 zone LED Annunciator.
FSRA-10C
10 zone LED Annunciator, with Common System Controls.
FSRSI
Remote System Indicator.
FSRZI-A
Remote Zone Indicator.
FSRZI-SA
Remote Zone Indicator.
FSAT1
Single gang annunciator trim plate.
FSAT2
Double gang annunciator trim plate.
FSAT3
Three gang annunciator trim plate.
FSAT4
Four gang annunciator trim plate.
FSUIM
Common Function Graphic Driver / Interface - 9 relays and 5 switch inputs for
common system indicators and controls.
FA-1000 SERIES ANNUNCIATOR
BACKBOX ENCLOSURES
BB-1001
Semi-Flush Backbox for Series 1000 Annunciators (Houses 1 Module), White Door & Black Backbox.
BB-1001WF
Flush Enclosure for Series 1000 Annunciators (Houses 1 Module) c/w Flush Mounting Backbox &
White Door.
BB-1002
Semi-Flush Backbox for Series 1000 Annunciators (Houses 2 Modules)White Door & Black Backbox.
BB-1002WF
Flush Enclosure for Series 1000 Annunciators (Houses 2 Modules)c/w Flush Mounting Backbox &
White Door.
BB-1003
Semi-Flush Backbox for Series 1000 Annunciators (Houses 3 Modules)White Door & Black Backbox.
BB-1008
Semi-Flush Backbox for Series 1000 Annunciators (Houses 8 Modules)White Door & Black Backbox.
MCH-001
BB-1000 Blank Panel Insert.
FA-1000 SERIES ANNUNCIATOR
WEATHERPROOF BACKBOX ENCLOSURES
BB-1001WP Semi-Flush Weatherproof Backbox for Series 1000 & FX-2000 Annunciators. (Houses 1 Module)
White Door & Black Backbox. Order TH-101 Heater Unit Seperately.
BB-1002WP Semi-Flush Weatherproof Backbox for Series 1000 & FX-2000 Annunciators. (Houses 2 Modules)
White Door &Black Backbox. Order TH-101 Heater Unit Seperately.
TH-101 Thermostat Heater for Sub-Zero Applications. Requires seperate 24 Vac power source (PS-24).
STI-7500H Weatherproof Kit for RAM-208 & RAM-216, c/w Gasket Kit & Lexan Cover, Keylock,
Horizontal Mount.
MIRCOM
NON-EXPANDABLE MULTIPLEXED ANNUNCIATORS
RTI-1 Remote Trouble Indicator
RAM-208 Remote Multiplex Annunciator c/w 8 Bi Coloured LED's. Common Control Features - Signal
Silence, Buzzer Silence, System Reset, Lamp Test. Indicators - AC On, Common Trouble & Signal
SilenceUsed with Series 200, 300, 1000 or FX-2000 - Mounts in 4 Gang Electrical Box.
RAM-216 Remote Multiplex Annunciator c/w 8 Bi Coloured LED's. Common Control Features - Signal Silence,
Buzzer Silence, System Reset, Lamp Test. Indicators - AC On, Common Trouble & Signal Silence.
Used with Series 200, 300, 1000 or FX-2000 - Mounts in 4 Gang Electrical Box.
RAM1016TZ Main Annunciator Chasis c/w 16 Bi-colored LED'sCommon Indicators - AC On, Common Trouble,
Auxiliary Disconnect, 2 Stage Acknowledge & General Alarm ActiveCommon Controls - Reset, Lamp
Test, Fire Drill, Auxiliary Disconnect, Local Buzzer & Signal Silence - Non Expandable - Mounts In
Series 1000 Enclosure.
RAM1016TZ Semi-Flush Backbox for Series 1000 Annunciators (Houses 3 Modules). White Door & Black Backbox.
MIRCOM FA-1000 SERIES GRAPHIC DRIVER
MGD-32 Master Graphic Driver Board c/w Fire Alarm Common Control Switch Inputs & LED Outputs
32 Supervised Outputs. Mounts in Graphic Wallbox, BB-5008 or BB-5014 Enclosures.
MGDS16/16 Master Display Driver Board c/w Fire Alarm Common Control Switches & LED's 16 Programmable
Zoned LED's, 16 Supervised Outputs, Interfaces to AGD-048 Graphic Driver Board - Mounts in
BB-5008 or BB-5014 Enclosure.
AGD-048 Adder Graphic Driver Board c/w 48 Supervised Outputs. Mounts in Graphic Wallbox, BB-5008 or
BB-5014 Enclosures.